Carsan Engineering, Inc.
221 Corporate Circle
Suite H
Golden, CO 80401
(303) 237-9608
|
Carsan Engineering, Inc.
QT112AXE
Xenon Power Supply
Specification
The QT112AXE power supply is designed to run xenon arc lamps in a constant-power mode. The output power is
adjustable from 90 to 140 Watts via a potentiometer on the circuit board. EMI line-filtering is built-in to the unit.
The supply includes a +12V output for powering external fans or electronics, a lamp over-voltage warning, lamp
over-voltage disable, and external disable.
Output power: 90 - 140 Watts, constant power
Output voltage compliance: 12.0 to 17.75 V operating.
Output regulation: output power held to within +/- 5% over all
input, output, and environmental conditions.
|



|
Output current: 6.5.0 to 10
Adc
Low-frequency output ripple: <2.0%„
Broadband output ripple: <0.4 Ap-p*
Efficiency: >70% at 112 W output, 120 VAC input
Thermal protection: ballast is disabled when heatsink temperature
exceeds 90 deg C. Unit will automatically restart after cooling
down.
Auxiliary output: +12V fan power, 250 mA max.
I/O Connector:
- Lamp Over-voltage Alert: active when lamp voltage reaches 17.5
+/- 0.175 VDC.
- External Lamp Disable
Over-voltage shutdown: Shuts down the lamp output if the lamp
voltage exceeds 17.75VDV for more than 1 second. |
Regulatory Compliance: Approved to UL2601 (E177225). Complies with EN55011 Class B Emissions. CE-marked.
|
Line Input:
|
: 100 - 240 VAC, +/- 10%, 47 - 63 Hz,
3.0 Arms max. |
|
Environmental:
|
0 deg C to 50 deg C operating. |
|
Altitude:
|
-1000 ft. to 12,000 ft. MSL. |
|
Vibration:
|
Survives 10Hz to 2kHz 1.0G sine sweep
on all axis. |
|
Non-operating Shock:
|
Survives 40.0G half sine 11mS pulses
on all axis. |
|
Weight:
|
2.1 lbs (0.95 Kg). |
|
Dimensions:
|
6.75" x 4.25",
2.75" tall (171mm x 108mm, 70mm tall). |
|
Ignitor:
|
25 KV ignition spike, positive
ignition.
Minimum repetition rate is 0.8 strikes/second at 90 VAC. Typical repetition
rate is 1.0 strikes/second (110 VAC).
Ignition pulses will continue for 10 seconds max. If ignitor disable
jumper is installed, ignition pulses will continue indefinitely until
lamp is lit. |
„ Low frequency ripple is measured in a DC to 1 KHz bandwidth
and stated as percent of DC output current.
* Broadband ripple is measured in a DC to 20 MHz bandwidth.
Specifications Subject
to change without notice.
| Product # 91439-00001 |
Revision C
|
|