Carsan Engineering, Inc.
221 Corporate Circle
Suite H
Golden, CO 80401
(303) 237-9608
|
Carsan Engineering, Inc.
CEP200AHX, CEP200BHX, CEP200CHX
200W Mercury-Xenon
Power Supply Specification
The CEP200 power supply is designed to run mercury-xenon arc lamps in a constant-power mode. The output power is adjustable from 180 to
315 Watts with a built-in potentiometer. Output power can also be controlled from an external voltage input. EMI line-filtering is built-in to the unit.
The supply includes an isolated +12V output for powering external fans or electronics. The CEP200 power supply is designed to switch to
constant current mode by removing two easily accessible shorting jumpers. Active Power Factor Correction to meet EMC limits for harmonic
current emissions, and limitations of voltage fluctuations and flicker.
Output power: 180 - 315 Watts, constant power
Output voltage compliance: 12.0 to 30.0 V operating, >250 VDC
during ignition.
Output regulation: output power held to within +/- 5% over all
input, output, and environmental conditions.
|



|
Output current: 8.0 to 18.0 Adc
Output ripple: <0.5%*
Efficiency: >70% at 220 W output, 120 VAC input
Thermal protection: ballast is disabled when temperature
exceeds 90 deg C.
Unit will automatically restart after cooling down.
Isolated Auxiliary output (SELV rated): +12.5VDC± 2%, 2.0 A max..
Optically Isolated Status & Control Connector (SELV rated):
- Remote Enable
- Lamp Lit Status
- Linear-response remote intensity control
- Lamp over-voltage/under-voltage indicator.
| Ground Leakage: |
AHX: <300 µA |
| BHX: <10 µA |
| CHX: <100 µA |
|
Regulatory Compliance: Approved to UL2601 (E177225). Complies with EN55011 Class B Emissions. Meets EN
61000-3-2 and EN61000-3-3. CE-marked.
|
Line Input:
|
100 - 240 VAC, ± 10%, 50-60 Hz, 4.4 Arms max. |
|
Environmental:
|
0 deg C to 40 deg C operating. |
|
Altitude:
|
-1000 ft. to 12,000 ft. MSL. |
|
Weight:
|
2.7 lbs (1.2 Kg). |
|
Dimensions:
|
6.50" x 4.65",
2.60" tall (165mm x 114mm, 66mm tall). |
|
Ignitor:
|
25 KV ignition spike. Positive-side
ignition.
Minimum repetition rate is 10 strikes/second at 90VAC.
Ignition pulses will continue for 6 ± 1 seconds. This feature
may be disabled via jumper, in which case the ignition pulses will
continue until the lamp ignites. |
|
Ignitor Life:
|
>100,000 strikes |
* ripple is measured in a DC to 20 MHz bandwidth.
Specifications Subject
to change without notice.
| Product # 91453-00002 |
Revision B
|
|