CE180AXE and CE180BXE

Xenon Power Supply Specification

The CE180 power supply is designed to run xenon arc lamps in a constant-current mode. The supply is designed to operate 175-watt xenon arc-lamps. The output current is adjustable from 10 to 15 Amps via a potentiometer on the circuit board. EMI line-filtering is built-in to the unit. The CE180BXE is the same as the A-model except it does not have Y-capacitors in the line filter section.

Output power: 110 - 224 Watts, constant current
Output voltage compliance: 11.0 to 17.0 V operating, >110 VDC during ignition.
Output regulation: output current held to within +/- 5% over all input, output, and environmental conditions.

Download Tech Sheet

PDF version

Output current: 10.0 to 15.0 Adc
Output ripple: <0.7 Ap-p *
Efficiency: >72% at 200 W output, 120 VAC input
Thermal protection: ballast is disabled when temperature exceeds 90 deg C. Unit will automatically restart after cooling down.
Auxiliary output (non-isolated): +12V fan power, 650 mA max,
12.0V to 12.8V at 250mA load.
Optically Isolated Status & Control Connector (UL-rated circuit)

  • Remote Enable
  • Lamp Lit Status
  • Remote Lamp Intensity Control
Ground Leakage:
AXE:
<300 µA at 136 VAC, <500 uA at 265 VAC
 
BXE:
<10 µA at all input voltages

Regulatory Compliance: Approved to UL2601 (E177225). Complies with EN55011 Class B Emissions. CE-marked.


Line Input:
100 - 240 VAC, +/- 10%, 47 - 63 Hz, 4.6 Arms max.
Input Surge Current:
<30 Amps peak at turn-on, for all input voltages.
Environmental:
0 deg C to 45 deg C operating.
Altitude:
-1000 ft. to 12,000 ft. MSL.
Weight:
2.5 lbs (1.14 Kg).
Dimensions:
6.00" x 4.15", 2.80" tall (152mm x 105mm, 71mm tall).
Ignitor:
25 - 30 KV ignition spike. Negative-side ignition.
Minimum repetition rate is 0.8 strikes/second at 90 VAC. Typical repetition rate is 1.2 strikes/second (120 VAC).
Ignition pulses will continue until lamp ignites.

* ripple is measured in a DC to 20 MHz bandwidth.

Specifications Subject to change without notice.

Product # 91435-00001
Revision G