Home Power Supplies/Ballasts
About Carsan
News & Events
Products
Careers
Contact Us

Carsan Engineering, Inc.
221 Corporate Circle
Suite H
Golden, CO 80401
(303) 237-9608

Carsan Engineering, Inc.

CE1O5AXE, CE1O5BXE, and CE1O5CXE

Power Supply Specification

The CE105 power supply is designed to run xenon arc lamps in a constant-current mode. The supply is designed to operate xenon arc-lamps in the 100 watt class, including the Cermax 75W and the XBO 100W. The output current is adjustable from 6.5 to 9.0 Amps via a potentiometer on the circuit board. EMI line-filtering is built-in to the unit. The CE180BXE is the same as the A-model except it does not have Y-capacitors in the line filter section. The CE18OCXE has smaller Y-capacitors to meet the 100 ~uA leakage requirement of many U.S. hospitals.

Output power: 62 - 144 Watts, constant current
Output voltage compliance: 9.5 to 16.0 V operating, >110 VDC during ignition.
Output regulation: output current held to within +/- 5% over all input, output, and environmental conditions.

Download Tech Sheet

PDF version

Output current: 6.5 to 9.0 Adc
Output ripple: <0.4 Ap-p *
Efficiency: >72% at 144 W output, 120 VAC input
Thermal protection: ballast is disabled when temperature exceeds 90 deg C. Unit will automatically restart after cooling down.
Auxiliary output (non-isolated): +12V fan power, 650 mA max. 12.OV to 12.8V at 250mA load.
Optically Isolated Status & Control Connector (UL-rated circuit)

  • Remote Enable
  • Lamp Lit Status
  • Remote Lamp Intensity Control
Ground Leakage:
AXE:
<300 uA at 136 VAC, <500 uA at 265 VAC
 
BXE:
<10 uA at all input voltages
 
CXE:
<100 uA at 136 VAC, <200 uA at 265 VAC

Regulatory Compliance: UL and CSA listed component (UL2601). Complies with EN55011, Class B, Group 1.


Line Input:
100 - 240 VAC, +/- 10%, 47 - 63 Hz, 2.1 Arms max.
Input Surge Current:
<30 Amps peak at turn-on, for all input voltages.
Environmental:
0 deg C to 45 deg C operating.
Altitude:
-1000 ft. to 12,000 ft. MSL.
Weight:
2.5 lbs (1.14 Kg).
Dimensions:
6.00" x 4.15", 2.80" tall (152mm x 105mm, 71mm tall).
Ignitor:
25 - 30 KV ignition spike. Negative-side ignition. Minimum repetition rate is 0.8 strikes/second at 90 VAC. Typical repetition rate is 1.2 strikes/second (120 VAC).
Ignition pulses will continue until lamp ignites.

* ripple is measured in a DC to 20 MHz bandwidth.

Specifications Subject to change without notice.

Product # 91435-00002
Revision F